Brand Name :HT SENSOR
Model Number :BPK-IV
Certification :ISO9001
Place of Origin :Baoji,China
MOQ :1
Price :Negotiable
Payment Terms :Western Union, L/C, T/T
Supply Ability :5000PCS/Month
Delivery Time :5-8 work days
Packaging Details :Standard Export Package
Model NO. :BPK-IV
Application :Industrial
Structure :Display Gauge
Transport Package :Standard Export Packing with Carton
Origin :Baoji, China
Warranty :2years
Measuring Range :Medium-pressure industrument
Switch :2 switch
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product Description

Industrial Digital Gauges with High/Low and High/High-High Alarms Switch

BPK-IV Pressure Gauge/Switch

Introduction:

The BPK-IV series controllers have display, control and transmission functions and have been used in many automatic control fields. Their main features are as follows:
1. Various RTDS, thermocouples or standard input signals can be selected (see table). The display range can be calibrated for nonlinear signals or set for linear signals.
2. Isolated transmission output is 12 bit resolution. Its scope can be set.
3. Two relay outputs, can be set high/low, high/high-high or low/low-low alarm action type.
2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms


Specification


1. Supply voltage:220VAC /24VDC10%);
2. Ambient temperature:0~50ºC; relative humidity:≤85%Non corrosive gas;
3. Input signal , display scope and relevant parameters:(see Table1)

Table 1

Input signal code Input signal Display scope Resolution Precision Input impedance
00 T TC 0~400ºC 1ºC 0.2% 100K
01 R TC 0~1600ºC 1ºC 0.2% 100K
02 J TC 0~1200ºC 1ºC 0.2% 100K
03 WRe3-WRe25 TC 0~2300ºC 1ºC 0.2% 100K
04 B TC 350~1800ºC 1ºC 0.2% 100K
05 S TC 0~1600ºC 1ºC 0.2% 100K
06 K TC 0~1300ºC 1ºC 0.2% 100K
07 E TC 0~900ºC 1ºC 0.2% 100K
08 Pt100 RTD -200.~600.0ºC 0.1ºC 0.2% (0.2mA)
09 Cu50 RTD -50.0~150.0ºC 0.1ºC 0.2% (0.2mA)
10 0~375Ω remote pressure Low and high limit of scope can be set from -1999 to 9999 Display scope is continuous from -1999 to 9999 using 16bit A/D sample 0.2% (0.2mA)
11 0~75mVcurrent divider 0.1% 100K
12 0~30mV 0.1% 100K
13 0~5Vstandard signal 0.1% 100K
14 1~5Vstandard signal 0.1% 100K
15 0~10Vstandard signal 0.1% 100K
16 0~10 mA standard signal 0.1% 20Ω
17 0~20 mA standard signal 0.1% 20Ω
18 4~20 mA standard signal 0.1% 20Ω
4. Analog current output and related parameters: (see Table 2)
Table 2
Transmitting output signal Current output Transmitting scope Isolated voltage Max.
resolution
Precision Load capacity Open- circuit voltage
00 4~20 mA Transmit data within scope to standard current signal 1500V 12bits 0.3% ≤500Ω 15V
01 0~20mA


This product is only manufactured into 4 ~ 20mA or 0 ~ 20mA output current signals. If the user needs the voltage output signal transmission output, it can be customized from the manufacturer or self-connected 250 or 500 ohm resistance for 1 ~ 5V or 0 ~ 5V, 0 ~ 10V voltage and resistance (note: the accuracy of the resistance directly affects the accuracy of the transmission output voltage).


5.Relay output contact capacity:(see Table 3)
Table3

250V/120V 120V/48V <48V Relay life
AC DC AC DC AC DC
>100000 times
Max. current (Resistive load) 3A 2A 4A 3A 5A 4A
Max .current (Inductive load) 0.3A 0.2A 0.4A 0.3A 0.5A 0.4A

6. External DC24V/30mA power. It can supply power to transmitter.
7. With automatic temperature compensation function for thermocouple sensor.
8. With disconnection protection function.

Model Outline dimension Panel output dimension(mm) Note
BPK-IIIS1 160×80×80(Horizontal ) 152+0.8×76+0.7
BPK-IV 96×48×112(horizontal) 92+0.7×44+0.5
BPK-IIIN1 80×160×80(vertical) 76+0.7×152+0.8
BPK-IIIN2 48×96×112(vertical) 44+0.5×92+0.7
BPK-IIIF1 96×96×112(square) 92+0.7×92+0.7
BPK-IIIF2 48×48×108(square) 44+0.5×44+0.5 With J2alarm lamp without J2 relay
BPK-IIIF3 72×72×112 67+0.7×67+0.7
2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms
2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms
2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms

2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms
company

2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms
2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms

2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms2 Switch Display Gauge Structure Industrial Digital Gauges with High / Low and High / High Alarms


Inquiry Cart 0