Baoji Hengtong Electronics Co., LTD

Baoji Hengtong Electronics Co., LTD manufacturer of the pressure sensor and pressure transmitter

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Water Level Transmitter /

BH93420-I Water Level Transmitter Oem 4-20mA Liquid Level Pressure Sensor

Contact Now
Baoji Hengtong Electronics Co., LTD
Visit Website
City:baoji
Province/State:Shaanxi
Country/Region:china
Contact Person:MrMerlin
Contact Now

BH93420-I Water Level Transmitter Oem 4-20mA Liquid Level Pressure Sensor

Ask Latest Price
Video Channel
Certification :CE,RoHs,ISO9001
Place of Origin :Baoji,China
Brand Name :HT sensor
MOQ :1
Price :Negotiable
Packaging Details :Standard Export Package
Delivery Time :5-8 work days
Payment Terms :Western Union, L/C, T/T
Supply Ability :1000-3000
Model Number :BH93420-I
Model NO. :BH93420-I
Output Form :4-20 mA or RS485
IP Rating :IP68
Housing Material :304 Stainess Stee
Net Weignt :0.3kg
Transport Package :Carton
Origin :Shaan Xi
HS Code :90261000
Installation Type :Submersible Type
Production Process :Diffused Silicon
Probe Type :Probe Type
Customization :Available | Customized Request
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

China Oem 4-20mA Liquid Transmitter Water Level Transmitter

BH93420-I WATER LEVEL TRANSMITTER

Introduction:

BH93420-I Sumersible liquid level transmitter/ water level transmitter that uses HT series diffused silicon isolation oil-filled core as its signal measuring element. It is designed with a full stainless steel housing and a compact one-piece structure. The sensing part of the transmitter that is immersed in the water is completely sealed with stainless steel, ensuring excellent waterproof performance. The product has undergone rigorous high and low-temperature compensation and aging tests, resulting in high reliability and excellent stability.
Product Features:
1. Full stainless steel housing, suitable for various testing environments
2. Immersion-type probe measurement, easy installation
3. Diverse output signal options

4. Explosion-proof marking: ExiaIICT6
5. High protection rate: IP68
6. PE or PU cable

Applications:

1. Compatible with 316LSS,noncorrosive liquids
2. Monitoring water levels in various applications such as sewage, industrial and municipal water, water tanks, wells, rivers, seawater, lakes, etc

3. Measuring fuel levels in diesel and fuel tanks

Performance Parameters:

Measurement Range 0~10m…400m
Overload ≤ 2 X of rated range
Accuracy @ 25ºC ±0.25% (Typ.) ±0.5% (Max.)
Repeatability ±0.03% (Typ.) ±0.05%FS (Max.)
Hysteresis ±0.03% (Typ.) ±0.05%FS (Max.)
Long-Term Stability ±0.2%F.S/year (Max.)
Zero Point Temperature Drift ±1.5%F.S(Typ.) ±2%F.S (Max.)
Full Scale Temperature Drift ±1.5%F.Sr(Typ.) ±2%F.S (Max.)
Compensation Temperature 0-50ºC (0-1m. 0-2m ); 0-70ºC
Operating Temperature -20~80ºC
Storage Temperature -30~100ºC
Vibration 10g,55Hz ~ 2kHz
Housing Material 1Cr18Ni9Ti
Diaphragm Material 316L Stainless Steel
Insulation Resistance >=100MΩ@100VDC
Explosion-proof Rating ExiaIICT6
Protection Rating IP67, IP68
O-Ring Seal Fluoro rubber
Weight ~0.3Kg (without cable)
Cable Material Polyethylene, Polyurethane

Output Signal

Supply Voltage Output Type
4~20mA 12~30VDC 2/3/4 wire
0~10/20mA
3 wire
0/1~5V
0/1~10V
0.5~4.5V 5VDC
RS485 Communication Protocol

BH93420-I Water Level Transmitter Oem 4-20mA Liquid Level Pressure SensorBH93420-I Water Level Transmitter Oem 4-20mA Liquid Level Pressure Sensor
BH93420-I Water Level Transmitter Oem 4-20mA Liquid Level Pressure Sensor
Installation tips:
1. The installation position should be reasonable, avoid external interference and damage, and facilitate maintenance and cleaning.
2. The equipment should be checked and calibrated before installation to ensure that it is working properly.
3. Overload and overpressure should be avoided during use, so as not to damage the equipment or affect the measurement accuracy.
4. Equipment should be regularly maintained and cleaned to keep it in good working condition.
5. Strong electromagnetic interference should be avoided during use, so as not to affect the measurement accuracy.
6. In the process of use should pay attention to explosion-proof measures to avoid dangerous accidents.
7. In the process of use, attention should be paid to the nature and temperature range of the liquid, and the appropriate equipment model and material should be selected.
8. When the equipment is damaged or faulty, it should be repaired or replaced in time to avoid affecting production and safety
Order Guide:
BH93420 Code Outline Construction
I Pressure Transmitter
Measurement Range 0~10m…400m
Code Power Supply
D1 24VDC
D2 5VDC
D3 Other
Code Output Signal
S1 4~20mADC S5 0~20mADC
S2 1~5VDC S6 0~10VDC
S3 0~5VDC S7 0.5~4.5VDC
S4 0~10mADC S8 RS485
Code Pressure Type
G Gauge Pressure
A Absolute Pressure
S Sealed Reference Pressure
Code Material
01 304 Stainless Steel
02 316L Stainless Steel
Code Cable Material
C1 PE
C2 PU